15%, accumulator sense, pump unload valve with check - pilot capacityCapacity: 15 gpm Cavity: T-21A
The accumulator sense, pump unload pilot valve is used to sense pressure in an accumulator at port 2 of the valve and when the pressure at port 2 reaches the valve setting, port 3 connects to port 4 to vent a relief valve and unload the pump. This valve has a 15% ratio between unload setting and reset; when pressure at port 2 falls below 85% of the valve setting, port 3 is blocked from port 4 and the pump will come back online to recharge the accumulator.